Hotel methodology
DEFRA
UK Government hotel factors
One factor per country for an occupied hotel room per night, published with the UK Government's conversion factors. In recent factor sets, the values are country medians from the Cornell Hotel Sustainability Benchmarking Index.
- Publisher
- UK Government (DESNZ)
- Best for
- UK-based reporting of hotel stays
- Result
- One total for all the room-nights, in CO₂e
- Energy scope
- Hotel operations
- Factor year
- Selectable; latest supported year by default
- Greenhouse gases
- CO₂e as published by the UK Government
How it works
- SQUAKE uses the UK Government factor for the hotel's country.
- London is the only city with its own factor.
- Recent factor sets use the rooms footprint of the Hotel Carbon Measurement Initiative (HCMI). Older sets used averages of the whole-hotel footprint, so results across that change are not like for like.
Unit and greenhouse gases
- Results are in CO₂e (carbon dioxide equivalent) for all the room-nights, in grams, kilograms or tonnes as requested.
- CO₂e covers the hotel's energy use, outsourced laundry and refrigerants, converted into the amount of CO₂ with the same warming effect.
Trip details used
When a detail is missing, SQUAKE uses the default.
| Detail | Default | Notes |
|---|---|---|
| Room-nights | Required | One room for one night counts as 1. |
| Country | United Kingdom | |
| City | None | Only London has its own factor. |
What is included
Included
- Energy used in the hotel
- Outsourced laundry and refrigerants
Not included
- Food and drink, purchased goods and guests' travel
Limitations
- Results are estimates from benchmark values. They are not a measurement of the actual emissions of an individual stay.
- One value per country, not specific to the hotel.
- A newer factor year does not always mean newer hotel data.
GHG Protocol, CSRD and ESRS reporting
- Scope 3: hotel stays on business trips can be reported in Scope 3, category 6 (business travel), of the GHG Protocol. The GHG Protocol makes them optional, so say whether you include them. ESRS E1 uses the GHG Protocol categories for Scope 3.
- Unit: the GHG Protocol and ESRS report emissions in tonnes of CO₂e. Request results in tonnes, or divide kilograms by 1,000.
- Global warming potentials: ESRS E1 asks for CO₂e based on the latest IPCC values over 100 years, currently those of the Sixth Assessment Report (AR6), and the GHG Protocol recommends the same. The UK methodology paper notes that the hotel factors are not all aligned with AR5 values. Say which values your figures use.
- Method: name the methodology and factor year next to the figure. Pin the factor year so the figure can be reproduced. Keep the same settings from year to year, or explain the change. The GHG Protocol asks you to describe the data sources, emission factors, global warming potentials, methods and assumptions behind each category.
- Estimates: results come from country values for typical hotels, not from data reported by the hotel. The GHG Protocol asks for the share of emissions calculated with data from suppliers or other value chain partners, and ESRS asks companies to explain estimates, including their assumptions and how uncertain they are.
- Credits and contributions: report the figure before any carbon credits or contributions. The GHG Protocol requires emissions to be reported independent of GHG trades such as carbon credits, and ESRS E1 also keeps credits out of the GHG figures. Report them separately.
Customer claims (EmpCo)
EU rules on environmental claims to consumers (Directive (EU) 2024/825, known as EmpCo) have applied since 27 September 2026.
- Present results as estimates and name the methodology, for example with a link to this page.
- If you compare hotels by their emissions, for example in a booking tool, tell customers how the comparison works: the methodology, what is compared and how often the data are updated. EU rules treat this as material information. Calculate every option with the same methodology and settings so the comparison is fair.
- Do not claim that a stay is climate neutral, or has a reduced or positive climate impact, because of carbon credits. EU rules ban claims based on offsetting.
- Describe contributions by what they fund, not as cancelling out the emissions of the stay.
- Avoid generic claims such as calling a stay green or eco-friendly. Use specific statements, such as the figure and the methodology.
This section and the one above are general guidance, not legal advice.
Sources
- UK Government: conversion factors for company reportinggov.uk
Every annual factor set, with its methodology paper.
- World Sustainable Hospitality Alliance: HCMIsustainablehospitalityalliance.org
The hotel measurement method behind the values.
- GHG Protocol: Scope 3 calculation guidanceghgprotocol.org
Category 6 (business travel), including optional hotel stays.
- GHG Protocol: Corporate Value Chain (Scope 3) Standardghgprotocol.org
What to report for each Scope 3 category, including data sources, the share of supplier data and biogenic CO₂.
- GHG Protocol: Global Warming Potential valuesghgprotocol.org
100-year global warming potentials from the IPCC, with the latest (AR6) values recommended.
- European Commission: corporate sustainability reportingfinance.ec.europa.eu
The CSRD and the European Sustainability Reporting Standards (ESRS), including the 2026 revision.
- EUR-Lex: Directive (EU) 2024/825 (EmpCo)eur-lex.europa.eu
EU rules against misleading environmental claims, applying since 27 September 2026.